ComplianceApp

Menu

Energy efficiency and insulation: what the NCC asks for

Editions covered: NCC 2022 (current in most states), NCC 2025 (WA, VIC, ACT) · Last reviewed 15 November 2026

The energy rating is set on paper at design stage, but it's won or lost on site. Gaps in batts, compressed insulation, unsealed downlights and missing door seals all cut real performance, and none of them show up in the rating certificate. This guide covers the NCC energy rules for houses, how the two compliance routes work, and the installation details trades are checked on. The rules differ a lot by state, so start with the state section.

Which edition?

  • NCC 2022 applies in NSW, QLD, SA, TAS and the NT.
  • NCC 2025 applies in WA, VIC and the ACT from 1 May 2026. WA and the ACT allow a 12-month transition.
  • The H6D2 structure and the Housing Provisions clauses quoted below are the same in both editions.

Where the rules are

  • NCC Volume Two H6P1 (thermal performance) and H6P2 (energy usage): the two Performance Requirements.
  • H6D2: the two deemed-to-satisfy routes:
    • Energy rating route: house energy rating software (NatHERS tools) under Specification 42, clauses S42C2 to S42C4.
    • Elemental route: ABCB Housing Provisions Parts 13.2 to 13.7.
  • AS/NZS 4859.1 (insulation materials): cited by number only.

Key requirements

  1. Thermal shell: 7 stars (S42C2(1)):

    • The house must reach 7 stars and stay within the separate heating and cooling load limits.
    • In climate zones 1 and 2, that drops to 6.5 stars with a qualifying covered outdoor living area, or 6 stars if that area also has a permanent ceiling fan.
    • The outdoor living area must:
      • adjoin a living area
      • be at least 12 m², with sides of at least 2.5 m and an opening height of at least 2.1 m
      • be open on at least one side (S42C2(3) to (5)).
  2. Whole-of-home: 60 (S42C3): the house must reach a whole-of-home rating of at least 60, using house energy rating software.

    • The rating counts heating and cooling, hot water, lighting, pool and spa pumps, and on-site solar and batteries.
    • Efficient appliances and solar can offset each other (NatHERS and the ABCB).
  3. Elemental route (H6D2(1)(b) and (2)(b)): instead of a rating, comply with:

    • Part 13.2: building fabric
    • Part 13.3: glazing and shading
    • Part 13.4: sealing
    • Part 13.5: ceiling fans
    • Parts 13.6 and 13.7: energy usage and services.

    For energy usage, the elemental route is only available for houses with a total floor area of no more than 500 m².

  4. Required R-values (HP 13.2.3 to 13.2.6): the minimum total R-values for roofs and ceilings, walls and floors depend on the climate zone and the construction. Read them from the table for your zone and don't use a rule of thumb.

  5. Installing insulation (HP 13.2.2):

    • Material: must comply with AS/NZS 4859.1.
    • Bulk insulation:
      • butts against or overlaps the next piece, butts against studs, joists and the like, and forms a continuous barrier
      • keeps its position and thickness. Compressing batts lowers their R-value (explanatory note).
      • where the wall below has no insulation, ceiling batts overlap the external wall by at least 50 mm.
      • must not interfere with the safe operation of services such as flues, downlights and transformers.
    • Reflective insulation:
      • has the airspace it needs
      • fits closely at openings and penetrations
      • is supported by framing
      • is lapped by at least 150 mm or taped at joins.
  6. Sealing (HP 13.4): these rules apply to a conditioned space, and to habitable rooms in climate zones 4 to 8.

    • External doors and openable windows (13.4.4):
      • must be sealed
      • doors need a draught protection device at the bottom edge
      • windows that meet the AS 2047 air-infiltration limits don't need extra seals.
    • Exhaust fans (13.4.5): need a sealing device, such as a self-closing damper or filter.
    • Ceilings, walls and floors (13.4.6): must be close-fitting at junctions, or sealed with architraves, skirting, cornice, foam or caulking. This includes around penetrations.

NCC 2019 difference: the previous minimum was 6 stars, with no whole-of-home requirement (Part 3.12).

How the states differ

  • NSW: energy efficiency for houses is set through BASIX, which applies to all residential dwelling types and forms part of the development application process (NSW Department of Planning).

    • NSW Part H6 replaces the national energy rules with three requirements:
      • insulation installation (Part 13.2)
      • building sealing (Part 13.4)
      • services (Part 13.7).
    • On 1 October 2023, the BASIX thermal performance standard rose from an average of 5.5–6 stars to 7 stars on NatHERS, aligned with NCC 2022 (NSW Department of Planning). Check the BASIX certificate for the job.
  • Tasmania: TAS Part H6 replaces the NCC 2022 energy rules with the NCC 2019 provisions. CBOS says new homes and extensions must meet 6 stars. The 7-star provisions have not been adopted.

  • Northern Territory: NT Part H6 limits the requirement to a 5-star energy rating, or the NT elemental provisions, from 1 October 2023 (ABCB adoption table). The NT has not adopted NCC 2025.

  • Victoria: VIC H6D2 follows the national routes. It also notes that a rainwater tank must be installed in a new Class 1 building under Victorian regulations. Sustainability Victoria describes the same 7-star and whole-of-home 60 targets.

  • Western Australia: on NCC 2025 (the NCC 2022 energy rules applied from 1 May 2025). A WA note to Section H says that, for alterations or extensions to an existing building, or a pool for an existing building, Parts 2.6 and 3.12.5 of NCC 2019 Volume Two (Amendment 1) may apply instead of Part H6. An "existing building" here is one that didn't have to meet the NCC 2022 (or later) energy rules. Ask your building surveyor whether it applies.

  • Queensland: the NCC 2022 energy rules started on 1 May 2024, through Queensland Development Code (QDC) 4.1. Housing and Public Works says the shell must achieve:

    • 7 stars for most houses and townhouses
    • 5 stars for eligible small homes under QDC 4.1
    • 6 stars for eligible houses with raised floors under QDC 4.1.

    A whole-of-home energy budget also applies.

  • South Australia: the 7-star and whole-of-home rules started on 1 October 2024 (PlanSA). Concessions apply:

    • Small and irregular allotments, worker and tourist accommodation, the Mount Barker Master Planned Neighbourhood Zone, and off-site-built homes of 70 m² or less (or in designated locations) can meet the NCC 2019 6-star thermal rules. They still need the NCC 2022 energy usage and condensation rules.
    • Alterations and additions to existing homes can use the NCC 2019 energy rules for development applications lodged before 1 May 2030.
  • ACT: the 7-star and whole-of-home 60 requirements started on 15 January 2024. ACT Planning says NCC 2025, adopted in May 2026, made no change to the energy rules for homes.

Ask the app

Upload a photo of ceiling batts, wall insulation or door seals, or ask:

  • "Do ceiling batts have to overlap the top plate?"
  • "What whole-of-home score does a new house need?"
  • "Does a house in Tasmania need 7 stars?"
  • "Do exhaust fans need dampers in climate zone 6?"
  • "Can I compress R2.5 wall batts into a 70 mm stud?"

Ask an insulation question · Builder · Glazing · Solar

Related checklists

FAQ

Does every new house need 7 stars? Not everywhere. The national NCC 2022 and 2025 rule is 7 stars, with lower targets in climate zones 1 and 2 when there is a qualifying outdoor living area. NSW uses BASIX, Tasmania requires 6 stars and the NT requires 5 stars. Queensland and South Australia also have lower targets for some eligible homes.

What is the whole-of-home rating? It's a score out of 100 for the home's energy use, including heating and cooling, hot water, lighting, pool and spa pumps, and any solar or battery. Houses need at least 60 (S42C3).

Can solar panels make up for a poor rating? Solar can offset appliance energy in the whole-of-home score, but not the 7-star thermal shell rating or its heating and cooling load limits. Those are separate tests (S42C2 and S42C3).

Does compressing insulation matter? Yes. The NCC explains that compressed insulation loses R-value. Insulation must keep its position and thickness, and the framing needs to suit the product (HP 13.2.2).

What seals are needed on doors and windows? In a conditioned space, or a habitable room in climate zones 4 to 8, external doors need a draught device at the bottom, and other edges need a seal. Windows that meet the AS 2047 air-infiltration limits don't need extra seals (HP 13.4.4).


This is general guidance, not a compliance check. Always check your approved plans, the energy rating or BASIX certificate, and the edition that applies to your permit, and confirm details with your certifier or building surveyor.

Based on content from the National Construction Code 2022 and 2025 (NCC Volume Two and the ABCB Housing Provisions), provided by the Australian Building Codes Board under the CC BY 4.0 licence. The ABCB does not endorse this guide. The standards the NCC references are cited and explained in our own words, not reproduced.

Sources

  • NCC 2022 Volume Two: H6P1, H6P2, H6D1, H6D2, Specification 42 (S42C2, S42C3), NSW Part H6 and its notes, TAS Part H6, NT Part H6, VIC H6D2
  • ABCB Housing Provisions Standard 2022 (1 May 2023): 13.2.2, 13.4.4 to 13.4.6. The 2025 versions were compared and no change was found.
  • NCC 2025 Volume Two, Part H6 (H6D2 and the WA explanatory note on existing buildings): https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-two/h-class-1-and-10-buildings/part-h6-energy-efficiency
  • ABCB, "New whole-of-home energy efficiency – what's it all about?": https://ncc.abcb.gov.au/news/2022/new-whole-home-energy-efficiency-whats-it-all-about
  • NatHERS FAQs: https://www.nathers.gov.au/resources/faqs
  • NSW Department of Planning, BASIX sustainability standards: https://www.planning.nsw.gov.au/policy-and-legislation/buildings/sustainable-buildings-sepp/sustainability-standards-residential-development-basix
  • CBOS Tasmania, Energy efficiency for new homes: https://cbos.tas.gov.au/topics/technical-regulation/building-standards/building-practitioners/energy-efficiency
  • Sustainability Victoria, "Seeing 7-stars": https://www.sustainability.vic.gov.au/energy-efficiency-and-reducing-emissions/building-or-renovating/7-star-homes-program/seeing-7-stars-new-home-energy-efficiency-standards-explained
  • Queensland Housing and Public Works, residential energy efficiency standards: https://www.hpw.qld.gov.au/initiatives/modern-homes/residential-energy-efficiency-standards
  • PlanSA, NCC 2022 modern homes provisions: https://plan.sa.gov.au/resources/building/ncc-2022-modern-homes-provisions
  • ACT Planning, Energy efficiency: https://www.planning.act.gov.au/professionals/regulation-and-responsibilities/responsibilities/energy-efficiency
  • ABCB, NCC 2022 state and territory adoption dates: https://ncc.abcb.gov.au/ncc-2022-state-and-territory-adoption-dates
  • ABCB, NCC 2025 adoption dates: https://ncc.abcb.gov.au/ncc-2025/ncc-2025-state-and-territory-adoption-information
  • Standards cited by number only: AS/NZS 4859.1, AS 2047